    The H-10 PRO is a highly responsive universal refrigerant leak detector using Bacharach’s tried-and-true heated diode sensor technology. It’s ultra-sensitive to all halogen-based, non-flammable CFC, HFC and HCFC refrigerants for reliable use in a wide range of refrigerant leak detection applications.

    The H-10 PRO has a long probe (4.5 ft.) for detecting leaks in hard-to-reach areas, visual and audible indicators to show relative leak sizes and an auto-zeroing feature (automatic mode only) for finding leaks in backgrounds where target gas is present. It has an internal sensor calibration reference to ensure optimum performance.

    Delivery Information

    All deliveries are despatched from our Auckland warehouse.

    Orders placed before 10am will be picked for despatch same day.

    Orders placed after 10am will be picked for despatch the following day.

    Delivery times are subject to location, with standard service being:

    Auckland: Next Day Delivery.

    North Island (Main Centres): Next Day Delivery.

    South Island (Main Centres): Delivery 2 days Following Despatch.

    Pricing & Orders
    • For pricing and orders please contact us.
    • This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

    Product Details

    Specifications
    Refrigerants Detected  [1] All CFC, HFC and HCFC refrigerants, including but not limited to: R-12, R-22, R-134a, R-404A, R-410A, R-502, R-507, HFO-1233zd, HFO-1234yf and HFO-1234ze
    Sensitivity[2] 0.006 oz/yr (stationary)
    0.1 oz/yr (moving per SAE J2791)
    Response Time 1 second
    Leak Indicators Visual (red LED in probe tip) and audible (via internal speaker or headphones)
    Automatic Background Adjustment Yes, in automatic mode
    Power 12 VDC internal rechargeable battery or via 100-240 VAC wall adapter/charger
    Run Time 3 hours (typical) on fully-charged batteryValue
    Size (H x W x D) Unit: 8.3 x 10.5 x 5.4 in. (21.1 x 26.7 x 13.7 cm)
    Probe: 4.5 ft. (1.37 m)Value
    Weight 5.1 lbs. (2.3 kg)
    Sensor Life [3] 1 year (typical)
    Operating Conditions 32 to 104 °F (0 to 40 °C), 10 to 90% RH (non-condensing), 1 ATM
    Warm-up Time 2 minutes (approximate)
    Approvals CE mark
    Warranty Instrument - 3 Years Sensor, Battery - 1 Year
    (Does not include probe tip, airflow balls, filters or leak reference bottle)
    [1] DO NOT use this device to detect for leaks of refrigerants which are rated as combustible/flammable gases (e.g. ASHRAE A2- or A3- rated refrigerants).
    [2] Sensitivity for R-12, R-22, R-124a, R-410A, R-404A and R-507 when unit is set to small leak setting, manual mode.
    [3] Based on normal use. Consistent and/or constant exposure to high levels of refrigerant will deteriorate the sensor life more quickly. Increasing the sensor heater will also impact sensor life.
    Data Sheet H-10 Pro data Sheet
    User Manual H-10 Pro User Manual
    You are currently viewing the New Zealand region's website. Choose another region: