H-10 Pro
The H-10 PRO is a highly responsive universal refrigerant leak detector using Bacharach’s tried-and-true heated diode sensor technology. It’s ultra-sensitive to all halogen-based, non-flammable CFC, HFC and HCFC refrigerants for reliable use in a wide range of refrigerant leak detection applications.
The H-10 PRO has a long probe (4.5 ft.) for detecting leaks in hard-to-reach areas, visual and audible indicators to show relative leak sizes and an auto-zeroing feature (automatic mode only) for finding leaks in backgrounds where target gas is present. It has an internal sensor calibration reference to ensure optimum performance.
Product Details
-
Key Features
- • Detects all CFC, HFC and HCFC refrigerants as low as 0.006 oz/yr, including R-410a and R-507
- • Dual power options allow battery operation for the best mobility or wall power for uninterrupted usage
- • Visual and audible indicators include an incremental flashing LED in the probe tip, an internal speaker and a headphone jack
| Specifications | |
|---|---|
| Refrigerants Detected [1] | All CFC, HFC and HCFC refrigerants, including but not limited to: R-12, R-22, R-134a, R-404A, R-410A, R-502, R-507, HFO-1233zd, HFO-1234yf and HFO-1234ze |
| Sensitivity[2] | 0.006 oz/yr (stationary) |
| 0.1 oz/yr (moving per SAE J2791) | |
| Response Time | 1 second |
| Leak Indicators | Visual (red LED in probe tip) and audible (via internal speaker or headphones) |
| Automatic Background Adjustment | Yes, in automatic mode |
| Power | 12 VDC internal rechargeable battery or via 100-240 VAC wall adapter/charger |
| Run Time | 3 hours (typical) on fully-charged batteryValue |
| Size (H x W x D) | Unit: 8.3 x 10.5 x 5.4 in. (21.1 x 26.7 x 13.7 cm) |
| Probe: 4.5 ft. (1.37 m)Value | |
| Weight | 5.1 lbs. (2.3 kg) |
| Sensor Life [3] | 1 year (typical) |
| Operating Conditions | 32 to 104 °F (0 to 40 °C), 10 to 90% RH (non-condensing), 1 ATM |
| Warm-up Time | 2 minutes (approximate) |
| Approvals | CE mark |
| Warranty | Instrument - 3 Years Sensor, Battery - 1 Year |
| (Does not include probe tip, airflow balls, filters or leak reference bottle) | |
| [1] DO NOT use this device to detect for leaks of refrigerants which are rated as combustible/flammable gases (e.g. ASHRAE A2- or A3- rated refrigerants). | |
| [2] Sensitivity for R-12, R-22, R-124a, R-410A, R-404A and R-507 when unit is set to small leak setting, manual mode. | |
| [3] Based on normal use. Consistent and/or constant exposure to high levels of refrigerant will deteriorate the sensor life more quickly. Increasing the sensor heater will also impact sensor life. | |
| Data Sheet | H-10 Pro data Sheet |
| User Manual | H-10 Pro User Manual |